Specialized AC Service Center

Professional Air Conditioner Service For Egyptian Climate

Egypt's specialized AC service company handling split, window, cassette, central, and inverter air conditioners. Refrigerant service, compressor repair, PCB diagnostics, and annual maintenance contracts. Critical service for Egypt's intense summer heat.

R32, R410A, R22 service
Inverter PCB specialists
Fast emergency service
Annual contracts available

AC Service Department

All formats • All refrigerants • Annual contracts

+40KAC units serviced
R32Eco-friendly refrigerant
4 hrsEmergency response
Inverter SpecialistsModern AC technology
Refrigerant ServiceLeak detection & charging
Deep CleaningCoil & filter service
Written Warranty6 months coverage
AC Types

Every AC format we service

From window units to multi-zone central systems

Split AC Systems

RESIDENTIAL STANDARD

Wall-mounted indoor unit with separate outdoor compressor. Most common format in Egyptian homes. Available in fixed-speed and inverter variants from 1.0 to 4.0 ton capacity.

  • Refrigerant leak from connection joints
  • Indoor unit fan motor failures
  • Capacitor service for compressor
  • Drain line clogs and water leaks

Inverter AC Systems

HIGH EFFICIENCY

Variable-speed compressor for optimal energy use. Samsung Wind-Free, LG DUAL Inverter, Daikin Inverter Smart. 30-40% energy savings vs fixed-speed but more complex repair.

  • Inverter PCB board failures
  • IPM module replacement
  • BLDC motor diagnostics
  • Pressure sensor calibration

Window AC Units

BUDGET SEGMENT

All-in-one units installed in window openings. Toshiba, LG, Sharp, Carrier. Simpler than splits but require attention to chassis seal and condensate management.

  • Chassis vibration and rattling
  • Condenser fan motor service
  • Capacitor replacement
  • Drain pan cleaning

Cassette AC Units

COMMERCIAL & PREMIUM

Ceiling-recessed units common in offices, restaurants, and luxury homes. 4-way airflow distribution. Daikin, Carrier, Trane, LG commercial. Specialized installation and service.

  • Drain pump and float sensor
  • Ceiling-suspended servicing access
  • Multi-airflow direction motors
  • Wired controller calibration

Central AC Systems

WHOLE-HOUSE

Ducted central air systems for villas, large homes, and commercial buildings. Higher capacity (5+ tons), professional installation, annual maintenance critical for performance.

  • Ductwork inspection and sealing
  • Multi-zone damper service
  • Large compressor servicing
  • Smart thermostat integration

Portable AC Units

FLEXIBLE COOLING

Movable units with exhaust hose. No installation required. Common in rentals, offices, and supplemental cooling. Service different from fixed installations.

  • Exhaust hose seal and routing
  • Internal condensate evaporation
  • Compact compressor service
  • Caster and mobility components
Diagnostic Approach

7 most common AC failures

Presentation

Indoor unit fan blows, compressor running, but air output is warm or barely cool. Most urgent AC complaint in Egyptian summer (40°C+ ambient).

Root Causes

Refrigerant undercharge from leaks (most common). Dirty condenser coil restricting heat rejection. Compressor failed but motor still spinning. Reversing valve stuck (heat pump models).

Our Repair Approach

Pressure measurement at suction and discharge sides. Electronic leak detection on flare connections. Condenser deep cleaning before refrigerant top-up. Refrigerant by weight charging — never by pressure alone.

Presentation

Water dripping from indoor unit onto floor or furniture. Sometimes ice formation visible. Risk of property damage and electrical hazard.

Root Causes

Drain line clogged with algae and debris (most common). Drain pan cracked. Drain pump failure (cassette units). Refrigerant undercharge causing evaporator freezing then melting. Improper installation slope.

Our Repair Approach

Drain line flush with pressurized cleaning. Algae prevention treatment. Pan repair or replacement. Refrigerant verification. We carry replacement drain pumps for Daikin, Carrier, LG cassette units.

Presentation

Indoor unit runs but outdoor compressor doesn't start. Sometimes loud humming followed by trip. Circuit breaker may trip immediately on AC start.

Root Causes

Compressor capacitor failed (most common). Compressor motor seized. Contactor stuck or failed. Wiring damaged from rodents or weather. Inverter PCB failure.

Our Repair Approach

Capacitor uF measurement and replacement. Compressor winding resistance and ground fault testing. Contactor inspection. Wiring continuity verification. Inverter PCB component-level repair where possible.

Presentation

Grinding, rattling, screeching, or hissing from indoor or outdoor unit. May be intermittent or continuous. Often disturbs neighbors with outdoor unit noise.

Root Causes

Indoor fan motor bearing failure. Outdoor fan blade off-balance. Compressor mounting bolts loose. Refrigerant flow noise (low charge). Foreign objects in fan path.

Our Repair Approach

Stethoscope localization of noise source. Bearing replacement, fan blade rebalancing, compressor remount with vibration isolators. Refrigerant verification.

Presentation

AC starts and stops every few minutes (short cycling). Never reaches set temperature. Higher electricity consumption. Premature compressor wear.

Root Causes

Oversized AC for room (sizing error). Refrigerant overcharge or undercharge. Thermostat sensor placement issue. Dirty filter restricting airflow. Faulty thermistor.

Our Repair Approach

Filter cleaning first. Refrigerant verification. Thermistor resistance test at temperature. Sensor relocation if needed. Honest sizing assessment if oversizing is the issue.

Presentation

Musty, moldy, or foul odor from AC vents when running. Sometimes burning smell. Health concern, especially for asthma sufferers.

Root Causes

Mold growth on evaporator coil (most common). Bacterial biofilm in drain pan. Burning electrical components (urgent — turn off immediately). Dead animal in unit. Filter saturation.

Our Repair Approach

Deep coil cleaning with antimicrobial treatment. Drain pan sterilization. Filter replacement. Anti-microbial UV light installation for chronic cases. Burning smell requires immediate electrical inspection.

Presentation

Visible ice on indoor unit's evaporator coil or refrigerant lines. Reduced cooling output. Eventually water leaks when ice melts.

Root Causes

Restricted airflow (dirty filter, blocked return). Refrigerant undercharge. Indoor fan motor failure or low speed. Frozen drain causing back-up. Set temperature too low.

Our Repair Approach

Allow complete defrost first (no AC use for 4-6 hours). Filter and air path cleaning. Fan motor speed verification. Refrigerant pressure check. Settings adjustment.

Service Specializations

Component-level AC expertise

Refrigerant Service (R32, R410A, R22)

Electronic leak detection, recovery, evacuation to proper vacuum, charging by weight. We service all common refrigerants used in Egyptian market AC systems.

Inverter PCB Repair

Component-level repair on inverter boards. Capacitor replacement, IPM module swap, varistor service. Saves 60-70% vs board replacement on Daikin, Mitsubishi, LG, Samsung inverter ACs.

Deep Coil Cleaning

Chemical-free coil cleaning with antimicrobial treatment. Removes mold, dust, and biofilm. Restores 30-40% efficiency on neglected units. Recommended annually.

Compressor Service

Compressor diagnostic with current draw, winding resistance, ground fault testing. Replacement only when truly failed. Brazing and refrigerant work to manufacturer specs.

Fan Motor & Capacitor Service

Indoor and outdoor fan motor service. Capacitor uF measurement and OEM replacement. Bearing service for cassette and central units.

Annual Maintenance Contracts

Twice-yearly service contracts for residential and commercial clients. Spring and autumn service. Filter replacement, coil cleaning, refrigerant check, electrical inspection.

AC Care

6 practices to maximize AC efficiency

Clean filters monthly

Dirty filters reduce airflow by 30-50%, drastically increasing energy consumption and stressing components. Wash filters monthly during summer heavy use.

Set thermostat to 24-26°C

Each degree below 24°C increases energy use by 6-8%. 24-26°C is optimal for comfort and efficiency in Egyptian climate. Use ceiling fans for additional comfort.

Clean outdoor unit annually

Egyptian dust accumulates rapidly on outdoor condenser coils. Annual professional cleaning maintains heat rejection efficiency and extends compressor life.

Seal cooled spaces

Close doors and windows when AC is running. Insulate ducts in central systems. Block sun with curtains during peak heat. Reduces AC runtime by 20-30%.

Use timer and sleep modes

Don't run AC business hours unnecessarily. Use timer to start before you arrive home. Sleep mode reduces output overnight. Saves 25-40% on summer electricity bills.

Annual professional service

Spring service before summer + autumn service after summer. Catches issues early, maintains warranty validity, and extends unit lifespan from 8 to 12+ years.

Book Service

Stay cool with professional AC service

Fast emergency service. Inverter specialists. Annual contracts available. Written warranty on every job.

Book AC Service Call Service Center